Micro Motion-K-H-Series Hygienic Coriolis Meter H400F and 1500

Micro Motion H-Series Hygienic Coriolis Meter Consisting of H400F Sensor and 1500 Transmitter

仕様

Micro Motion H400F Hygienic Coriolis Meter, 4 Inch (DN100), 316L Stainless Steel, 15 RA Finish
Mass flow accuracy (Liquid)
Up to ±0.05% of rate
Mass flow repeatability (Liquid)
Up to ±0.025% of rate
Volume flow accuracy (Liquid)
Up to ±0.05% of rate
Volume flow repeatability (Liquid)
Up to ±0.025% of rate
Mass flow accuracy (Gas)
Up to ±0.35% of rate
Mass flow repeatability (Gas)
Up to ±0.175% of rate
Density accuracy (Liquid)
Up to ±0.0005 g/cm³ (±0.5 kg/m³)
Temperature accuracy
±1 °C ±0.5% of reading
Sensor maximum working pressure
1,450 psig (100 barg)
Meter approvals, calibrations, and certifications

•CSA
•IECEx
•ATEX
Micro Motion 1500コンパクト型制御室用単一変数流量トランスミッタ
使用可能な出力
モデル 1500:1 つの流速変数 (電流および周波数/パルス出力) を必要とする用途の場合
モデル2500:出力 (電流、周波数、およびディスクリート I/O) からの組み合わせで、複数の流量変数
ハウジング
ポリアミド PA 6.6
電源

•最低19.2~28.8VDC
•6.3W
•設置に関する(過電圧)カテゴリII、汚染レベル2規定の要件に準拠
入力/出力信号

•アクティブ4~20mA出力1基
•アクティブ周波数出力1基
HART
Bell 202信号は、第一mA出力で重畳回線になります
取り付けオプション
リモート取り付け(制御室のみ)
•35mmレールに取り付け
•センサは必ず接地してください
アプリケーションの種類

•連続的なプロセス制御
•二相流計測/混入ガス
•充填および注入
•計測器検証
危険場所認証
危険のない場所への設置に適しています。

機能

Micro Motion H400F Hygienic Coriolis Meter, 4 Inch (DN100), 316L Stainless Steel, 15 RA Finish
  • Minimize variability in process control with superior sensitivity in a compact design
  • Ensure product consistency and quality with superior density measurement
  • Enable fast product change-over with self-draining design and superior temperature stability
  • Choose from options including highly polished 316L stainless steel with a surface finish up to 15 Ra
  • Gain real-time and in-process measurement integrity assurance with Smart Meter Verification
  • Realize superior two-phase flow capabilities for batching, loading and entrained air applications from compact, hygienic SST transmitter housings
  • Broad range of meter approvals and certifications, including; CSA (Class 1 Div 1 groups C and D, Class 1 Div 2 groups A, B, C and D), ATEX, IECEx, Ingress Protection 66/67, and NAMUR
  • Use in SIP, CIP and sanitary environments where 3-A compliance is required
Micro Motion 1500コンパクト型制御室用単一変数流量トランスミッタ
  • 35 mm DIN レール使用のリモートマウント伝送器で配線費用を削減
  • 制御室で場所を取りません。コリオリ伝送器は、通常 1.0 ft³ 以上のスペースが必要ですが、わずか 0.03 ft³で済みます
  • センサへの 4 線式接続で電源用と信号用の構成を簡素化
  • MVD デジタル処理を使用した気泡混入や空のバッチアプリケーション向けの性能診断
  • 処理実行中のセンサの健全性をインラインで検証します。二次参照なしの現場での真の検証です

文書と図面

Micro Motion H400F Hygienic Coriolis Meter, 4 Inch (DN100), 316L Stainless Steel, 15 RA Finish
Micro Motion 1500コンパクト型制御室用単一変数流量トランスミッタ